¢Ã F100 Tacky. Lowest powdered Latex Finger Cots
 
Specifications
Raw materials; Natural Rubber Latex DRC 60%(Biodegradable)
 

Chemical used(Non-toxic/Non-hazardous)

Sulfur
ZnO 
EZ 
TT 

TiO©ü 
WINGSTAY-L 
TP 
Organic pigment

Zinc oxide
Zinc diethyl dithiocarbamate
Tetramethythiuram disulfide
Tamol
Titanium dioxide
Butylated reactive product of p-cresol and dicyclopentadiene
Sodium dibuty ditiocarbamate£¦nbsp;
 

Quality Standard

D 3772-92 ASTM Standard Specification for Rubber Finger Cots
IEST-RP-CC005.2 Gloves and Fingercots used in cleanroom and other controlled environment
D 573-88(1984)el ASTM Standard test method for Rubber deterioration in an air oven 21 CFR 170

 

Dimensions

 
Length (mm)
Width (mm)    
Thickness (mm)

Small
70 ¡¾ 2
24 ¡¾ 2
0.09 ¡¾ 0.03

Medium
70 ¡¾ 2
28 ¡¾ 2
0.09 ¡¾ 0.03

Large
70 ¡¾ 2
30 ¡¾ 2
0.09 ¡¾ 0.03

X-Large
70 ¡¾ 2
34.5 ¡¾ 2.5
0.09 ¡¾ 0.03

 

Physical property

Tensile Strength (Mpa) > 24
Elongation at break (%) > 700

 

Physical Appearance

White color, Pink color(optional)
Rolled tip, Unrolled tip without rim(optional)
Smooth surface, Textured surface at tip area(optional)
Pre-powdered with food grade powder

 

Test result FTIR & NON VOLATILE

Silicone oil : Not Detected.
Amides : Not Detected.
DOP : Not Detected.
NVR : ¡Â 0.07 mg/cm©÷.
¡Ø IEST-RP-CC005.2.

 

Test result of ION CHROMATOGRAPHY

 ¥ìg/cm©ø
[ F+Cl+Br ] < 3.10
[ NO©ý] < 0.14
[ SO©þ] < 0.30
[ PO©þ] < 0.03
[ Na ] < 0.85

  

ESD test

Static charge: < 50v
Tribo-Electric charge: 150v 
Surface resistivity: 10 9 ~ 10 11 §Ù/cm©÷ (Anti-static type only)
Decay time: < 3.0sec.
(From 1000v to 100v)
(60 + 5% R.H)

 

Test result of BACTERIOLOGICAL EXAMINATION

Standard plate count @37¡ÆC for 48 hrs (per gram sample) : < 10
Yeast (per gram sample) : < 10
Mould (per gram sample) : < 10

 

Health Hazard Data

This product made of Natural Rubber Latex may cause allergic reaction on human skin. Do not continue using if skin irritation occurs. Those sensitive Latex allergic shall use other alternative hand protection such as nitrile finger cots or gloves.

 

Bio Compatibility

The chemical formulation of the fingercots and surface lubricating materials do not contain any substances normally known to be harmful to the user or to any person with whom the fingercots contact. 

¡¡

Storage Instructions

Fingercots should be kept in a cool, dry place to prolong shelf life. Should avoid direct sunlight. 
Fingercots are easily contaminated while in contact with copper materials.

¡¡

-----------------------------------------------------------------------------------

 

¡ã  TOP